-40%

Niles Black APC-2, Current Sensing AC Switching Outlet System, FG00254

$ 13.19

Availability: 100 in stock
  • Return shipping will be paid by: Buyer
  • Brand: APC
  • Type: Surge Protector
  • Refund will be given as: Money Back
  • Condition: NILES APC-2 IS IN EXCELLENT FUNCTIONING USED CONDITION WITH SOME SURFACE WEAR (AS SHOWN)
  • Restocking Fee: No
  • All returns accepted: Returns Accepted
  • Item must be returned within: 14 Days
  • Color: Black

    Description

    Niles Black APC-2, Current Sensing AC Switching Outlet System, FG00254
    NILES APC-2 IS IN EXCELLENT FUNCTIONING USED CONDITION WITH SOME SURFACE WEAR (AS SHOWN)
    *DETAILED PICTURES PROVIDED - WHAT YOU SEE IS WHAT U GET*
    *INTERNATIONAL SHIPPING DONE THROUGH EBAY GLOBAL SHIP*
    *HAPPY BIDDING!!!*
    Niles APC-2 Black Current Sensing Outlet Switcher (APC2) [FG00254]
    Three AC Outlets - One Current Sensing (requires Min. 30W Current Draw Differential Between On/off For Reliable Sensing), One Switched, One Unswitched
    1,500W Maximum (all Outlets Combined)
    APC-2 Is Activated By Current Sensing Outlet Or 12Volt DC Signal (100mA Minimum)
    12Volt Control Output for Activating Other Niles Audio Devices like SPK-1, AVS-2, AC-3, Or RFS-1
    N.O. (normally Open) And N.C. (normally Closed) Relay Contacts for Controlling Other Devices Such As Electric Screens, Motorized Lifts and Drapes, Etc.
    Relay Contacts Rated At One Amp, 30V Max. AC/DC
    Dimensions: 8" Wide X 2-3/4" High X 7" Deep
    UPC Code:
    760514002548
    MPN Code:
    APC-2
    Brands
    Niles, SSV Works
    Color
    Black
    In
    electrical engineering
    ,
    current sensing
    is any one of several techniques used to measure electric current. The measurement of current ranges from picoamps to tens of thousands of amperes. The selection of a current sensing method depends on requirements such as magnitude,
    accuracy
    , bandwidth, robustness, cost, isolation or size. The current value may be directly displayed by an instrument, or converted to digital form for use by a monitoring or control system.
    Current sensing techniques include shunt resistor, current transformers and
    Rogowski coils
    , magnetic-field based transducers and others.
    Current sensor
    [
    edit
    ]
    A current sensor is a device that detects
    electric current
    in a wire and generates a signal proportional to that current. The generated signal could be analog voltage or current or a digital output. The generated signal can be then used to display the measured current in an ammeter, or can be stored for further analysis in a data acquisition system, or can be used for the purpose of control.
    The sensed current and the output signal can be:
    Alternating current
    input,
    analog output, which duplicates the wave shape of the sensed current.
    bipolar output, which duplicates the wave shape of the sensed current.
    unipolar output, which is proportional to the average or RMS value of the sensed current.
    Direct current
    input,
    unipolar, with a unipolar output, which duplicates the wave shape of the sensed current
    digital output, which switches when the sensed current exceeds a certain threshold
    Requirements in current measurement
    [
    edit
    ]
    Current sensing technologies must fulfill various requirements, for various applications. Generally, the common requirements are:
    High sensitivity
    High accuracy and linearity
    Wide bandwidth
    DC and AC measurement
    Low temperature drift
    Interference rejection
    IC packaging
    Low power consumption
    Low price
    Techniques
    [
    edit
    ]
    The measurement of the electric current can be classified depending upon the underlying fundamental physical principles such as,
    Faraday's Law
    of Induction
    Magnetic field sensors
    Faraday Effect
    Hall effect sensor
    .
    Transformer
    or
    current clamp
    meter, (suitable for AC current only).
    Fluxgate sensor
    , (suitable for AC or DC current).
    Shunt resistor
    , whose voltage is directly proportional to the current through it.
    Fiber optic current sensor
    , using an
    interferometer
    to measure the phase change in the light produced by a magnetic field.
    Rogowski coil
    , electrical device for measuring alternating current (AC) or high speed current pulses.
    Giant Magnetoresistance(GMR): Magnetic field sensor suitable for AC & DC Current with higher accuracy than Hall Effect. Placed parallel to the magnetic field.
    The
    Hall Effect
    current sensor is a type of current sensor which is based on the Hall Effect phenomenon discovered by
    Edwin Hall
    in 1879. Hall Effect current sensors can measure AC, DC, or pulsating current.
    Shunt resistors
    [
    edit
    ]
    Ohm's Law
    is the observation that the voltage drop across a resistor is proportional to the current going through it.
    This relationship can be used to sense currents. Sensors based on this simple relationship are well known for their lower costs, and reliability due to this simple principle.
    Shunt resistor
    The common and simple approach to current sensing is the use of a shunt resistor. The voltage drop across the shunt is proportional to its current flow. Both alternating currents (AC) and direct currents (DC) can be measured with the shunt resistor. The high performance coaxial shunt have been widely used for many applications fast rise-time transient currents and high amplitudes but, highly integrated electronic devices prefer low-cost surface mounted devices (SMDs),
    [1]
    because of their small sizes and relatively low prices. The
    parasitic inductance
    present in the shunt affects high precision current measurement. Although this affects only the magnitude of the impedance at relatively high frequency, but also its effect on the phase at line frequency causes a noticeable error at a low power factor. The low cost and high reliability make the low resistance current shunt a very popular choice for current measurement system. The major disadvantage of using the shunt is that fundamentally a shunt is a resistive element, the power loss is thus proportional to the square of the current passing through it and consequently it is a rarity amongst high current measurements. Fast-response for measuring high-impulse or heavy-surge currents is the common requirement for shunt resistors. In 1981 Malewski,
    [2]
    designed a circuit to eliminate the skin effect and later in 1999 the flat-strap sandwich shunt (FSSS)
    [3]
    was introduced from a flat-strap sandwich resistor. The properties of the FSSS in terms of response time, power loss and frequency characteristics, are the same as the shunt resistor but the cost is lower and the construction technique is less sophisticated, compared to Malewski and the coaxial shunt.
    Trace Resistance sensing
    [
    edit
    ]
    The intrinsic resistance of a conducting element, usually a copper trace in Printed circuit Board (
    PCB
    ) can be used as sensing element instead of a shunt resistor.
    [4]
    Since no additional resistor is required this approach promises a low-cost and space saving configuration with no additional power losses either. Naturally, the voltage drop of a copper trace is very low due to its very low resistance, making the presence of a high gain amplifier mandatory in order to get a useful signal. There are several physical effects which may alter the current measurement process: thermal drift of the copper trace, initial conditions of the trace resistance etc. Therefore, this approach is not suitable for applications that require a reasonable accuracy due to the large thermal drift. In order to overcome the problems associated with the temperature drift, a digital controller can be used for thermal drift compensation and calibration of the copper trace.
    [5]
    A significant drawback of this kind of current sensor is the unavoidable electrical connection between the current to be measured and the sense circuit. By employing a so-called
    isolation amplifier
    , electrical isolation can be added. However, these amplifiers are expensive and can also deteriorate the bandwidth, accuracy and thermal drift of the original current sensing technique. For these reasons, current sensing techniques based on physical principles that provide intrinsic electrical isolation deliver a better performance at lower costs in applications where isolation is required.
    Current sensor based on Faraday's Law
    [
    edit
    ]
    Faraday's Law of induction – that states: the total electromotive force induced in a closed circuit is proportional to the time rate of change of the total magnetic flux linking the circuit – has been largely employed in current sensing techniques. Two major sensing devices based on Faraday’s law are Current transformers (CTs) and Rogowski coils. These sensors provide an intrinsic electrical isolation between the current to be measured and the output signal, thus making these current sensing devices mandatory, where safety standards demand electrical isolation.
    Current transformer
    [
    edit
    ]
    Main article:
    Current transformer
    Current transformers used as part of metering equipment for three-phase 400A electricity supply
    The CT is based on the principle of a transformer and converts a high primary current into a smaller secondary current and is common among high AC current measurement system. As this device is a passive device, no extra driving circuitry is needed in its implementation. Another major advantage is that it can measure very high current while consuming little power. The disadvantage of the CT is that a very high primary current or a substantial DC component in the current can saturate the ferrite material used in the core ultimately corrupting the signal. Another problem is that once the core is magnetized, it will contain
    hysteresis
    and the accuracy will degrade unless it is demagnetized again.
    Rogowski coil
    [
    edit
    ]
    See also:
    Rogowski coil
    Rogowsky coil
    Rogowski coil is based on the principle of Faraday’s law of induction and the output voltage V
    out
    of the Rogowski coil is determined by integrating the current I
    c
    to be measured. It is given by,
    {\displaystyle V_{\rm {out}}=-k{\frac {NA\mu _{0}}{2\pi r}}I_{\rm {c}}+v_{\rm {out}}(0)}
    where A is the cross-sectional area of the coil and N is the number of turns. The Rogowski coil has a low sensitivity due to the absence of a high permeability magnetic core that the current transformer can take advantage of. However, this can be compensated for by adding more turns on the Rogowski coil or using an integrator with a higher gain k. More turns increase the
    self-capacitance
    and
    self-inductance
    , and higher integrator gain means an amplifier with a large gain-bandwidth product. As always in engineering, trade-offs must be made depending on specific applications.
    Magnetic field sensors
    [
    edit
    ]
    Hall effect
    [
    edit
    ]
    Main article:
    Hall effect sensor
    Hall effect sensors are devices based on the Hall-effect, which was discovered by
    Edwin Hall
    in 1879 based on the physical principle of the Lorentz force. They are activated by an external magnetic field. In this generalized device, the Hall sensor senses the magnetic field produced by the magnetic system. This system responds to the quantity to be sensed (current, temperature, position, velocity, etc.) through the input interface. The Hall element is the basic magnetic field sensor. It requires signal conditioning to make the output usable for most applications. The signal conditioning electronics needed are an amplifier stage and temperature compensation. Voltage regulation is needed when operating from an unregulated supply. If the Hall voltage is measured when no magnetic field is present, the output should be zero. However, if voltage at each output terminal is measured with respect to ground, a non-zero voltage will appear. This is the common mode voltage (CMV), and is the same at each output terminal. The output interface then converts the electrical signal from the Hall sensor; the Hall voltage: a signal that is significant to the application context. The Hall voltage is a low level signal on the order of 30 μvolts in the presence of one gauss magnetic field. This low-level output requires an amplifier with low noise, high input impedance and moderate gain. A
    differential amplifier
    with these characteristics can be readily integrated with the Hall element using standard bipolar transistor technology. Temperature compensation is also easily integrated.
    Fluxgate sensors
    [
    edit
    ]
    Fluxgate Technology principle
    Fluxgate sensors or Saturable
    inductor
    current sensors work on the same measurement principle as Hall-effect-based current sensors: the magnetic field created by the primary current to be measured is detected by a specific sensing element. The design of the saturable inductor current sensor is similar to that of a closed-loop Hall-effect current sensor; the only difference is that this method uses the saturable inductor instead of the Hall-effect sensor in the air gap.
    Saturable inductor current sensor is based on the detection of an
    inductance
    change. The saturable inductor is made of small and thin magnetic core wound with a coil around it. The saturable inductor operates into its saturation region. It is designed in such a way that the external and internal flux density will affect its saturation level. Change in the saturation level of a saturable inductor will alter core’s
    permeability
    and, consequently, its inductance L. The value of saturable inductance (L) is high at low currents (based on the permeability of the core) and low at high currents (the core permeability becomes unity when saturated). Fluxgate detectors rely on the property of many magnetic materials to exhibit a non-linear relationship between the magnetic field strength H and the flux density B.
    [6]
    In this technique, high frequency performance is achieved by using two cores without air gaps. One of the two main cores is used to create a saturable inductor and the other is used to create a high frequency transformer effect. In another approach, three cores can be used without air gap. Two of the three cores are used to create saturable inductor, and the third core is used to create a high frequency transformer effect. Advantages of saturable inductor sensors include high resolution, high accuracy, low offset and gain drift, and large bandwidth (up to 500 kHz). Drawbacks of saturable inductor technologies include limited bandwidth for simpler design, relatively high secondary power consumption, and risk of current or voltage noise injection into the primary conductor.
    Magneto-resistive current sensor
    [
    edit
    ]
    See also:
    Magnetoresistance
    and
    Giant magnetoresistance
    A magneto-resistor (MR) is a two terminal device which changes its resistance parabolically with applied magnetic field. This variation of the resistance of MR due to the magnetic field is known as the
    Magnetoresistive
    Effect. It is possible to build structures in which the
    electrical resistance
    varies as a function of applied magnetic field. These structures can be used as magnetic sensors. Normally these resistors are assembled in a bridge configuration to compensate for thermal drift.
    [7]
    Popular magneto resistance-based sensors are: Anisotropic Magneto Resistance (AMR),
    Giant Magneto Resistance
    (GMR), Giant Magneto Impendence (GMI) and Tunnel Magneto Resistance (TMR). All these MR-based sensors have higher sensitivity compared to Hall-effect sensors. Despite this, these sensors (GMR, CMR, and TMR) are still more expensive than Hall-effect devices, have serious drawbacks related with nonlinear behavior, distinct thermal drift, and a very strong external field can permanently alter the sensor behavior (GMR). GMI and TMR sensors are even more sensitive than GMR based sensors, but still in the test phase and no commercial products are available as of 2016-06.